Alcohol Testing
    AlcoScreen
    BreathScan
    QED A150
    Breathalyzers
Adulteration
Basic Metabolic Status
    Creatinine Serum Test
    I-STAT Controls
Cancer Screening
Cardiac Markers
Clinical Chemistry Reagents
Cholesterol
    Cholestech LDX Supplies
    Cholestech LDX Cassettes
    CardioChek-Medical
    CardioChek-Home
CLIA Waived Drug Tests
CLIA Proficiency Testing
Diabetes Testing
    LifesScan
Drug Test Dip Cards
    ACON Drug Testing Kits
    Fastect II 1-Panel Drug Tests
    Fastect II 4-Panel Drug Testing
    Instant-View Drug Tests
    QuikTox Drug Test
    RapidTOX Drug Test
Drug Testing Controls
Drug Testing Cups
    CLIAwaived Inc. Cup
    EZ Split Cup
    iCup
    QuickScreen Cup
    ToxCup
    DrugCheck Cup
Drug Testing Generic
    Single Dip Cards
    Single Drug Cassettes
    Multi Panel Dip Card
    Multi-Line Cassettes
    EZ Split Drug Test Cups
Drug Testing Hair
Drug Testing Other
    Adulteration
    Buprenorphine
    Oxycodone
    Propoxyphene
    Saliva
    Supplies
    Steroid
Fecal Occult Testing
Glucose Testing
HemoCue Supplies
HemoCue VET Supplies
Hemoglobin/Hematocrit Testing
Infectious Disease Testing
    Chlamydia
    HIV/AIDS
    Herpes
    Influenza/FLU
    Legionella
    Mono
    RSV
    Vaginalis
Ketone Testing
Lead Testing
Medical Supplies
MicroAlbumin Testing
Monthly Specials Drug Test Kits
Monthly Specials Clinical Tests
Nebulizers
Nicotine Testing
Ovulation Testing
Oximeters
Pregnancy Testing
    CLIAwaived Inc.
    Cassette
    Dip Strip
    Controls
Prothrombin Monitoring
    Professionals
    Home Use PT/INR Products
Thyroid Testing
Urinalysis Testing
    Bayer Products
    1-11 Parameter Strips
CPT Codes-Reimbursement
Drug - Clinical Testing Catalogs



  CORPORATE
CLIAwaived.com
11578 Sorrento Valley Road
Suite 25/26
San Diego, CA 92121
858-481-5031 tel
801-720-7568 fax


SALES
Toll Free 1-888-882-7739
Email: info@cliawaived.com





 
Hemoccult SENSA Fecal Occult Blood Test

   

BKM-SK-64151
Hemoccult SENSA Fecal Occult Blood Test
(100/Box)
Hemoccult SENSA Fecal Occult Blood Test, non invasive, easy to use test Performance Monitor area on each test offers built in quality control. (FDA 510K#: K880499)

$85.50

Qty:

Insert


 

Hemoccult SENSA Test:

-The Hemoccult SENSA test is a rapid, convenient and qualitative method for detecting fecal occult blood which may be indicative of gastrointestinal disease. It is not a test for colorectal cancer or any other specific disease.

-Hemoccult SENSA has been proven to give the highest clinical sensitivity readings (92% for colorectal cancer)1,2, helping significantly in the early detection of pre-cancerous adenomas and colorectal cancers. Hemoccult SENSA has a more intense blue reaction, providing better readability than regular Hemoccult and other FOBTs.

Highest clinical sensitivity readings (92%)

Improved readability, intense blue reaction

14-day on-slide stability

Each Box Contains:

-100 Slides

-100 Applicator Sticks

-Two 15 mL bottles of Hemoccult SENSA developer

More Info

Frequently Asked Questions (FAQs)

Q: What are the dietary restrictions?

A: For seven days before and during the stool collection period avoid non-steroidal anti-inflammatory drugs such as ibuprofen, naproxen or aspirin (more than one adult aspirin per day); 3 days prior to and during the test period, do not eat red meat (no beef, lamb or liver in any form) or take vitamin C in excess of 250 mg/day.

Q: How should this product be stored?

A: At room temperature, away from heat, light and volatile chemicals.

Q: How long is the fecal sample stable?

A: The fecal sample must be tested within 14 days of application to the slide.

Q: What is the difference between Hemoccult and Hemoccult SENSA?

A: Hemoccult SENSA is more sensitive.

Q: May I test alternate samples (gastric fluid, breast secretions, etc.) on this test?

A: No - this test has only been validated for human fecal samples. Other sample types may not give accurate results. For gastric occult blood testing - refer to our Gastroccult® product page.

Q: Can the developers for Hemoccult and Hemoccult SENSA be interchanged?

A: No, the chemical composition of these products is not the same.

Q: Can I interchange different lot numbers of slides & developer?

A: Yes, the components are NOT lot-specific. Use ONLY Hemoccult Developer (yellow & green striping, yellow cap) with Hemoccult slides, and ONLY Hemoccult SENSA Developer (blue & green striping, blue cap) with Hemoccult SENSA slides.

Q: What is the CPT code?

A: The CPT code is 82270 for "Fecal Occult Blood, Diagnostic", or G0107 for "Fecal Occult Blood, Screening".

Q: What is the reimbursement?

A: The 2000 National Cap is $3.50.

Q: What types of configurations are available?

A: See the Product Instructions.

Q: How do you interpret a positive test?

A: Any blue color "on" or "touching" the fecal sample is considered a positive test; Performance Monitor® must function correctly for a valid test. Color interpretation charts are available from Technical Marketing.

Q: Seeing "blue" slides prior to adding developer; is this test card considered invalid?

A: "Blue" slides can be seen when storage is incorrect; review storage. However, blue slides can be interpreted as valid tests if upon adding developer, the guaiac paper around the fecal smear reverts back to white. Interpret a positive test when any blue color is seen "on" or "touching" the fecal sample; Performance Monitor must function correctly for a valid test. (Note: Do not interpret the blue ring that migrates outward as a positive test.) BLUE SLIDES SHOULD BE REPORTED TO TECHNICAL MARKETING.

Q: Is external Quality Control available/required?

A: No, the Performance Monitor is an "analyte" or "reactivity" control (derived from hemoglobin) and provides adequate QC. However, if laboratory procedures manual or local regulations require external control testing, follow those guidelines.

CLIA Classification Analytes CPT Code Test Methodology Sample
Volume
Time to
Result
Units in which the test is reported
Waived Occult Blood G0107, 82270 GUAIAC Thin smear of fecal sample Within 60 seconds N/A - QUALITATIVE RESULT


Hemoccult® SENSA® detects abnormal occult bleeding associated with gastrointestinal disorders more reliably than standard fecal occult blood tests (FOBTs). The Hemoccult® SENSA®  test includes an enhancer which makes the test more sensitive and more readable than standard Hemoccult® and other FOBTs. With enhanced blood detection and improved readability, the use of Hemoccult® SENSA® results in significantly improved detection of adenomas and colorectal cancer. All Hemoccult® SENSA® tests are CLIA Waived.

  • All Hemoccult® SENSA® tests are CLIA Waived

  • Clinical sensitivity for colorectal cancer 92%, specificity 97%

  • Results within 60 seconds

  • Enhanced sensitivity compared to standard FOBTs

  • Over 300 publications supporting Hemoccult® products

  • A variety of package configurations satisfy individual physician needs

  • Improved overall readability and precision
  • Performance Monitor® area on each tests offers built-in quality control

Order No. SK-64151

Qty: 100

CPT*:   Reimbursement shown indicates National Average

CLIA: FDA Cleared/CLIAwaived 

Contact: (888)-882-7739